Physical Data

Continuous static load0.30 N/mm²
Peak loads (rare, short-term loads)0.40 N/mm²
Static modulus of elasticityBased on
EN 826
0.5 - 1.7N/mm²Tangential modulus, see figure “Modulus of elasticity”*
Dynamic modulus of elasticityBased on
DIN 53513
2.5 - 7.0N/mm²Depending on frequency, load and thickness, see figure “dynamic stiffness“*
Mechanical loss factorDIN 535130.16[-]Load-, amplitude- and frequency-dependent
Compression setBased on
DIN EN ISO 1856
3.4%Measured 30 minutes after decompression with 50% deformation / 23 °C after 72 hrs
Tensile strengthBased on
DIN EN ISO 1798
0.6N/mm²
Elongation at breakBased on
DIN EN ISO 1798
65%
Tear resistanceBased on
DIN ISO 34-1
5.0N/mm
Fire behaviourDIN 4102
DIN EN 13501
B2
E
[-]
[-]
Normal flammability
Sliding frictionBSW-laboratory
BSW-laboratory
0.7
0.8
[-]
[-]
Steel (dry)
Concrete (dry)
Compression hardnessBased on
DIN EN ISO 3386-2
415kPaCompressive stress at 25 % deformation
test specimen h = 60 mm
Rebound elasticityBased on
DIN EN ISO 8307
36%dependent on thickness,
test specimen h = 60 mm
Force reductionDIN EN 1490465%dependent on thickness,
test specimen h = 60 mm
Ozone resistanceDIN EN ISO 17025Cracking stage 0[-]